Download Catalogue     

You have no items in your shopping cart.

Subtotal: Ex GST $0.00

Search results for '25 cal face shield'

Search results for: '25 cal face shield'

Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
Grid  List 
  1. BMFD/50-160 Stop Suit 50-160mm

    ALROC BMFD/50-160 tool to carry out tools stop.
    It’s a great tool to prepare the cable ready for joint installation, termination or connector.
    Cable diameter from Ø50 to 160mm.
    Length 345mm, Width 245mm, Height 50mm.

  2. CWF3-60 Cable Stripper 16-58mm

    ALROC CWF3/60 tool removes outer sheath and insulation. 
    CWF3/6 is a great tool to prepare the cable ready for joint installation, termination or connector.
    Cable diameter from Ø16 to 58mm - Ø0.630-2.2

  3. BMF-40-90 Stop Suit 40-90mm

    ALROC BMF-40-90 tool to carry out tools stop. 
    It’s a great tool to prepare the cable ready for joint installation, termination or connector. 
    Cable diameter from Ø40 to 90mm. 

  4. FC2310CPTIXTHY Cable & PhaseVocal ID

    Fameca FC2310 Cable Identifier for De-energised Cable. De-energized three phase cable identifier and phaser - Voice over cable ID,Network Mapper
  5. 40 cal Arc Flash Kit -Extra Large

    Stanco TTEK 40 cal Arc Flash kit complete with FR quick adjust helmet to keep the hood from moving on the head. Long coat & Velcro leggings for quick fit, good for muddy work environments or where boots are not allowed to be removed. Kit comes with
  6. Ins Stick Kit 4 x 1.5m w/Bag

    Hylec's operating insulating stick 1.5m screw type are made from high quality foam-cored tubes that can be used on high voltage applications. With a universal (sunrise) end fitting, you can easily attach different adaptors to apply i.e. Earthing,

  7. HRC2 Blue Coveralls Arc Flash kit 12 cal

    Cat 2 Arc Flash Kit containing:

    Glove Kit, Carry Bag, Face shield Rating HRC2 >8 cal/cm2, helmet, Coveralls colour Royal Blue, Regeltex Rubber Electrical Gloves GLB Class 0 1000V Beige, 999 HRC2 Arc Flash Leather Outer gloves.

    <

  8. 12 cal 50 inch Coat BLUE Size XL

    A/F 12.41 cal 50 inch Coat Size XL
  9. 12.4 cal Hood & Visor

    A/F 12.4 cal Hood & Visor
  10. A/F 21 cal 50 inch Coat Size XL

    A/F 21 cal 50 inch Coat Size XL
  11. Trousers 107 N/Blue S451 112R 12.4cal

    Trousers 107 N/Blue S451 112R 12.4cal
    Ex GST $59.00
  12. Glove Ins Cl2 Sz10 L16inchBeige 17kV

    Insulating Glove Class "2" 17,000kV 41cm (16 inch) Beige. IEC 60903

    The Regeltex Class "2" glove is for electrical work with maximum voltage of 17,000 volts. It is an essential piece of PPE designed to protect workers interacting with expo

  13. Glove Ins Cl00 Sz10 L14inchBlack 500V

    Insulating Glove Class 00 500V 36cm (14inch) Black IEC 60903

    The Regeltex Class "00" glove is for electrical work with maximum voltage of 500 volts. It is an essential piece of PPE designed to protect workers interacting with exposed 

  14. Glove Outer 44Cal bell cuff Sz10 L12inch

    Glove Outer 44Cal bell cuff Sz10 L12inch
  15. Glove Ins Cl2, 17kV 74.5 cal Sz10 16Com"

    Composite Insulating gloves with ARC Flash protection. Standards IEC 60903, 61482-1-2, ASTM F2675

    The Regeltex Class 2 composite glove is for electrical work with maximum voltage of 17,000 volts. It is an essential pi

  16. Glove Ins Cl3, 26.5kV 73.2cal Sz10 16 C"

    Composite Insulating Gloves with ARC Flash protection. Standards IEC 60903, 61482-1-2, ASTM F2675

    The Class 3 composite glove is for electrical work with maximum voltage of 26,600 volts. It is an essential piece of PPE designed to protect

  17. Glove Ins Cl4, 36kV 87.7cal Sz10 16 Com"

    Composite Insulating gloves with ARC Flash protection The Regeltex Class 4 composite glove is for electrical work with maximum voltage of 36,000 volts. It is an essential piece of PPE designed to protect workers interacting with exposed High Volta
  18. AF HRC2 Helmet Kit XL10cal 112R

    AF HRC2 Helmet Kit XL10cal 112R
  19. Stanco HRC2 Arc Flash 12.4 cal Kit 2

    Stanco HRC2 Arc Flash 12.4 cal Kit 2. Contents: Knee Length 50" Coat, GCA Class 0 Electrical Mechanical Arc Flash Gloves, Standard Hood, Australian Designed Standard helmet (for under hood use) , 15" Leggings, GB50 Deluxe

  20. 12.4 cal Suit Kit c/w Gear Bag XL

    A/F 12.4 cal Suit Kit c/w Std Hood XL

    • Stanco Arc Flash ( PPE ) Protective Switching Suit - Clothing Kit. Conforming to Standard: NFPA 70E HRC/CAT 4 ASTM D6413. Available Standard Cal ratings: 8, 12, 21, 25, 40, 44, 57 & 74cal.
  21. A/F 12.4 cal Economy Suit Kit XL

    A/F 12.4 cal Economy Suit Kit XL
  22. A/F 21 cal Suit Kit c/w Std Hood XL

    A/F 21 cal Suit Kit c/w Std Hood XL
  23. 21 cal Economy Suit Kit XL

    A/F 21 cal Economy Suit Kit XL
  24. 40cal ArcFlash Kit CoatTrouserGlove HRC4

    Stanco TTK 40 cal Arc Flash kit complete with FR quick adjust helmet to keep the hood from moving on the head. Waist length coat & sleeveless Bib / Trousers made from Westex material, providing excellent protection. Kit comes with US214 Arc Flas
  25. HRC4 TTEK Suit Kit. Fan Hood L

    51.3cal TTEK Suit Kit. Fan Hood L
  26. 62.1 cal TTEK Suit Kit. Fan Hood M

    62.1 cal TTEK Suit Kit. Fan Hood M
  27. XLPE Insulation Chamfer tool 14-40mm

    Alroc XLPE enables a chamfer of 30 mm at the extremity of the insulation of MV cables. For 14-40mm cable diameter.

  28. XLPE Insulation Cable Stripper 38-60mm

    Alroc XLPE enable a chamfer of 30 mm at the extremity of the insulation of MV cables. For 38 - 60mm cable diameter.
  29. Tool 2x2 w/95 & 25 Ends (2402357)

    Tool 2x2 w/95 & 25 Ends (2402357)
  30. Insulated cutting pliers 190mm

    Insulating composite cable cutting pliers.
    Standards: EN 60900 / IEC 60900.
    Guaranteed up to 1000V.
    Length 190mm, Weight 165g
    Apllication range: Opening 22mm, Aluminium 35mm2 Copper 16mm2

  31. LH2 Insulation Cable Stripper 38-60mm

    Alroc LH2 cable tools used by MV-HV jointers to remove the insulation to prepare the cable ready for the installation of joints, terminations or connectors. 
    Maximum cutting depth: 17mm.
    Length 425mm, Width 105mm, Height 85mm.<

  32. LV 3 phase shorting Earth No cable

    LV 3 phase shorting earth no cable
  33. Cable Cutter w/end plastic

    INSULATED RATCHET CABLE CUTTER Ø 25 MM WITH INSULATING HEAD COVER 290MM L ALUM 300MMSQ & COPPER 240MMSQ - EN 60900 / IEC 60900.  this tool can be used with a wedge with groove 5544E.

  34. Micro Clamp with handle for tightening

    Micro Clamp with handle for tightening
  35. SRC Adjustable Scoring Stylus Gold

    The gold SRC stylus can remove the peelable semi-conductor without touching the primary insulation located underneath.
    4 scoring depths: 0.4mm / 0.7mm / 0.9mm / 1.1mm.
    Diameter: ø14 - 58 mm.
    Must be used with the following to

  36. XLPE Insulation Cable Stripper 60-80mm

    Alroc LH3 cable tools used by MV-HV jointers to remove the insulation.
    Prepare the cable ready for the installation of joints, terminations or connectors.
    Maximum cutting depth: 24mm.
    Cable diameter from 60 to 80mm.
    Length 460m

  37. SRC-D Adjustable Scoring Stylus Silver

    The silver SRC-D stylus can remove the peelable semi-conductor without touching the primary insulation located underneath.
    4 scoring depths: 0.4mm / 0.7mm / 0.9mm / 1.1mm.
    Diameter: ø16 - 58 mm.
    Must be used with the followin

  38. XLPE Insulation Cable Stripper 80-110mm

    Alroc LH4 cable tools used by MV-HV jointers to remove the insulation.
    Prepare the cable ready for the installation of joints, terminations or connectors.
    Maximum cutting depth: 29mm
    Cable diameter from 80 to 110mm.
    Length 640m

  39. SCH Insulation Chamfering Stylus Green

    The green SCH stylus can make a chamfer on the extremity of the primary insulation.
    Diameter: ø16 - 60 mm.
    Must be used with the following tools: MF1+/25, MF1+/60, MF3/40, MF3/60, MF3/40-SR, MF3/60-SR, MF3/40-C, MF3/60-C

  40. Arrester Default Detector

    Online partial discharge detector for overhead accessories The ADD™ allows online partial discharge detection on medium voltage accessories such as: Arresters, dry type transformers, bushings, insulators, etc… The partial discharge level is d
  41. Portable Discharge Detector

    Partial Discharge Detection and Localization System for Power Transformers The AE-150™ is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors’ data. The AE-150™ has many acquisition modes
  42. Phase Displacement

    Real three phase automatic ratio tester for power transformer The ART-3Dâ„¢ series of ratio meters are high precision instruments, designed to measure turn ratios, phase displacements, excitation currents of single phase and three phase power, di
  43. Switch Disc SLTL4A-3AS/3X/4 1ph

    NH strip-type fuse-switch-disconnector SLTL4A-3AS/3X/4 690V Rated operating current: 1250A Size: NH4a Busbar distance: 185mm poles: 3
  44. NH1 Baseplate mount 250A 1200V 3P #

    NH Fuse Disconnector TL1AG-3/265/1200V
    Ex GST $653.00
  45. Switch Disc 1ph SL3-3x/3A-630A unboxed

    Switch Fuse Disconnector Vertical 1ph SL3-3x/3A-630A unboxed
  46. 24 cal Premium Balaclava

    ARCCAG24ARC FLASH BALACLAVA - ATPV 24,7 CAL/CM²EN ISO 11612 / EN 61482-1-2 / ASTM F1506 / NFPA70EUse:Provides protection of the face and the neck against thermal hazards, especially against burn hazards from an arc flash. It does not spread t

  47. 12 cal Premium Balaclava

    ARCCAG10 FLAME RESISTANT AND ARC FLASH RESISTANT BALACLAVA, ATPV 12,1 CAL/CM²EN ISO 11612 (A1 AND A2 B1 C1 F1) / IEC 61482- 2 / EN 61482-1-2 (CLASS 1 ACCORDING TO BOX TEST), ASTM F1959-05 (12,1 CAL/CM², HAF 81,6% ACCORDING TO OPEN ARC ME

  48. Glove Ins Cl1, 7.5kV 42.2 cal Sz10 16 C"

    Composite Insulating gloves with ARC Flash protection. Standards IEC 60903, 61482-1-2, ASTM F2675

    The Class 1 composite glove is for electrical work with maximum voltage of 7,500 volts. It is an essential piece of PPE designed to protect w

  49. Glove Ins Cl00, 500V 26.3cal Sz10 14Com"

    Composite Insulating gloves with ARC Flash protection The Class 00 composite glove is for electrical work with maximum voltage of 500 volts. It is an essential piece of PPE designed to protect workers interacting with exposed High Voltage electric
  50. Road Shell Cable Cover 2x90-4x40mm

    Road Shell Cable Cover - suits Warm Climate Low Profile 120mm. Two channels 92mm & four channels 40mm

  51. Lead Sheath Spreader LV & MV Cables

    The Alroc EVP enables the user to flare and spread the lead sheath or the tabs made from the lead sheath. Spread without damaging underlying layers.

  52. OHL Probes w/handle1.25m for TAG780 IP2X

    OHL Probes w/handle1.25m for TAG780 IP2X
  53. Probe Substation Style 715mmL for TAG780

    Probe Substation Style 715mmL for TAG780
  54. CATALOGUE - Hylec NZ Summary Catalogue New Zealand 2017

    Electrical Network Product Solutions
  55. LV Cable Stripper 6 Sections 16-150mm

    ALROC stripping Tool. 6 sections from 16 to 150mm².
    Low voltage cable stripper 6 sections. For overhead cable. Enables the user to remove the insulation.
    Sections : 16 - 25 - 35 - 54,6 - 70 - 150m²
    Length 130mm, Width 130m

  56. DSP Peelable Semiconductor Lifter

    The DSP tool remove and catch the peelable semiconductor at the end of cable.
    Diameter: ø10 - 80 mm.
    Can be used with the following tools: MF1+/25, SR, SRC, MF1+/60, SRC-D, MF3/40, MF3/60.

  57. MV Bonded semicon scraper 15-240mm

    The MV Bonded semicon is a very reliable product, well designed using high quality steel and aluminium. This tool is targeted to get a very long-life duration.

  58. 3P Fuse Switch to NH1 250A Din Fuse #

    Fuse Switch Disc LTL1-3/9 250A 3P
  59. Fused Switch to suit NH00 up to 160A

    Switch Dis LTL00-1/9 160A 690V 1P
  60. KETO-1-2/F Size 1 250A FSD

    KETO-1-2/F Size 1 250A FSD
  61. KETO-1-3/F/OGS NH-FSD 3ph 250A/325A

    KETO-1-3/F/OGS NH-FSD 3ph 250A/325A
  62. Rubber Goods Cleaner 200ml Spray Bottle

    Regeltex RGX-1704 is a quick drying professional rubber cleaner in a ready to use 200ml spray bottle.RGX is specifically developed to properly clean rubber insulating materials such as gloves and mats. For best results we recommend to us

  63. Plastic UV Glove Box Suit Classes 0-4

    The BGT Sibille Safe Glove box has been designed for the safe storage and protection of electrical gloves. This unit is portable with folding handle, it can also be wall mounted for use in electrical substations, technical rooms etc. 

  64. Pneumatic Glove Tester

    TESTER FOR INSULATING GLOVES

    Use: The purpose of the tester is to ensure that the glove is absolutely air-tight.

     

  65. ArcFlash Gloves 32 cal(non ins.)size 9

    ArcFlash Gloves 32 cal(non ins.)size 9
  66. ArcFlash Gloves 32cal(non ins.)size10

    ArcFlash Gloves 32cal(non ins.)size10
  67. ArcFlash Gloves 32 cal(non ins.)size11

    ArcFlash Gloves 32 cal(non ins.)size11
  68. ArcFlash Gloves 32 cal(non ins.)size12

    ArcFlash Gloves 32 cal(non ins.)size12
  69. PFlex 9.4 Cal HRC2 FR Glove size 10 (XL)

    9.4 cal  HRC2  Kevlar Glove - Cut and Fire Resistant (FR)  Size 10

    See below for product detail >>

  70. Aladin Electric Field Detector 10-400kV

    Individual electric field detection with headlamp.
    For MV Overhead lines 10 000 to 69 000V, work from elevated platforms only.
    Provide extra safety level for workers operating near energized equipment.
    Dimensions: 87x60x34mm.
    W

  71. Glove Bag Canvas 17inch (425mm) OPEN TOP

    Glove Bag canvas 17inch (425mm)
  72. Glove Bag Vinyl 17inch(425mm) w/clip EOL

    Hylec glove bag is made from PVC material. This will suit to store all classes of insulating glove and leather over glove with 36cm (14 inch) length from Class 00 to 4.

    Ex GST $39.00
  73. Voltage detector DC 400-3600V 157621

    FAMECA Bipolar voltage detector. Composed with a probe and a pole that allows the detection of DC voltages as well as AC.
    Rated voltage: 400V to 3600V.
    Meta case size: 450x345x127mm
    Weight: 1.75kg.

  74. HV voltage detector 250 to 440kV

    FAMECA high voltage DC detector. Compact optical and acoustic detector with LEDs.
    Rated voltage: 250 000 to 440 000 V DC
    Length: 350mm, Diameter: 80mm
    Weight: 0.550kg.

  75. HV voltage detector 450 to 800kV

    FAMECA high voltage DC detector. Compact optical and acoustic detector with LEDs.
    Rated voltage: 450 000 to 800 000 V DC
    Length: 350mm, Diameter: 80mm
    Weight: 0.550kg.

  76. HV voltage detector 50 to 100kV

    FAMECA high voltage DC detector. Compact optical and acoustic detector with LEDs.
    Rated voltage: 50 000 to 100 000 V DC
    Length: 350mm, Diameter: 80mm
    Weight: 0.550kg.

  77. Indoor Kit with TAG5010 4-230kV QLD

    Fameca's Wireless Contact Phase Detector supplied by Hylec is a contact phase detector for three phase network with nominal voltages from 4kV up to 230kV. It uses 2 wireless instruments a Transmitter and a Receiver that is pared together and has a

  78. Phasor5K Series 4-230kV+case50Hz TV1.8kV

    TAG5010 4-230 AU 50HZ Also available in 4-132kV and 11-33kV. Fameca HV Wireless Phasor Wide Range contact, Outdoor, On Board test, sunrise head, audio visual. 50Hz proven in Australian conditions for over 20 years

    &n
  79. Portable Life Saving Kit 36kV

    VESELECTRICAL SAFETY KIT 36kV

    Use : The electrical safety kit allows to assist people in presence of electrical hazards, up to 25 kV network with model VES25 or up to 36 kV network with model VES36.

    This kit is particularly suitabl

  80. 20m Equipotential Bonding Earthing reel

    Earthing cable reels for equipotential bonding: USE For equipotential bonding. Protection against electrostatic charges and shocks due to lightning. Tank trucks, tanks.
  81. HV Rescue Hook 2m 90kV

    Insulated High Voltage Rescue Hook/Crook 2m is an essential piece of equipment designed for rescuing a person/technician who is being subjected to an electrical shock working on category 1, 2 and 3 substations. It is used to grasp the injured pers

  82. HV Rescue Hook 1.5m 45kV

    Insulated High Voltage Rescue Hook/Crook 1.5m is an essential piece of equipment designed for rescuing a person/technician who is being subjected to an electrical shock working on category 1, 2 and 3 substations. It is used to grasp the injured pe

Page:
  1. 1
  2. 2
  3. 3
  4. 4
  5. 5
Grid  List