You have no items in your shopping cart.
Search results for '25 cal arc flash face shield'
Search results for: '25 cal arc flash face shield'
-
Ins. Stick 1.0m w/sunrise head
FAMECA's operating insulating stick 1.0m length supplied by Hylec are made from high quality foam-cored tubes that can be used on high voltage applications. With a universal (sunrise) end fitting, you can easily attach different adaptors to apply
-
CWB/18-60 Cable Stripper 18-60mm
Alroc MV Bonded Semicon Removal Tool for 18 - 60mm outside diameter. Removes the bonded semi-conducting screen without the need of lubrication in joints, terminations or connectors work.
-
CAMF4 Cable Stripper 40-49mm
The Alroc CAMF4/40-90-BBCF enables the user:
-To remove the bonded semiconductor
-To remove the Primary/XLPE insulation
Diameter of the cable from 40 to 90 mm. -
ASCR2 Cable Stripper 20-50mm
ALROC stripping tool for cable from Ø20 to 50mm.
Removes the bonded semi-conductor from MV and HV cables.
Creates a chamfer on the semi-conductor layer to facilitate the installation of joint, termination or connector.
Adjust -
ASCR1 Cable Stripper 14-40mm
ALROC stripping tool for cable from Ø14 to 40mm.
Removes the bonded semi-conductor from MV and HV cables.
Creates a chamfer on the semi-conductor layer to facilitate the installation of joint, termination or connector.
Adjust -
Insulated long nose angled pliers 210mm
Insulating half-round bent nose cable cutting pliers with ceramic blades.
Standards: EN 60900 / IEC 60900
Guaranteed up to 1000VInsul. Stick 1.5m Sunrise Head
FAMECA's operating insulating stick 1.5m length supplied by Hylec are made from high quality foam-cored tubes that can be used on high voltage applications. With a universal (sunrise) end fitting, you can easily attach different adaptors to apply
BRMRD1E Cable Stripper 14-40mm
ALROC stripping Tool - insulation 14-40mm OD.
Medium Voltage Energy cable stripper that enables the user to remove the insulation and set up cutting length.
Insulation thickness capacity: 9mm.
Length 270mm, Width 100mm, Height 165mmHRC2 Blue Coveralls Arc Flash kit 12 cal
Cat 2 Arc Flash Kit containing:
Glove Kit, Carry Bag, Face shield Rating HRC2 >8 cal/cm2, helmet, Coveralls colour Royal Blue, Regeltex Rubber Electrical Gloves GLB Class 0 1000V Beige, 999 HRC2 Arc Flash Leather Outer gloves.
<
40 cal Arc Flash Kit -Extra Large
Stanco TTEK 40 cal Arc Flash kit complete with FR quick adjust helmet to keep the hood from moving on the head. Long coat & Velcro leggings for quick fit, good for muddy work environments or where boots are not allowed to be removed. Kit comes withIns Stick Kit 4 x 1.5m w/Bag
Hylec's operating insulating stick 1.5m screw type are made from high quality foam-cored tubes that can be used on high voltage applications. With a universal (sunrise) end fitting, you can easily attach different adaptors to apply i.e. Earthing,
Glove Ins Cl2 Sz10 L16inchBeige 17kV
Insulating Glove Class "2" 17,000kV 41cm (16 inch) Beige. IEC 60903
The Regeltex Class "2" glove is for electrical work with maximum voltage of 17,000 volts. It is an essential piece of PPE designed to protect workers interacting with expo
Glove Ins Cl00 Sz10 L14inchBlack 500V
Insulating Glove Class 00 500V 36cm (14inch) Black IEC 60903
The Regeltex Class "00" glove is for electrical work with maximum voltage of 500 volts. It is an essential piece of PPE designed to protect workers interacting with exposed
Glove Ins Cl2, 17kV 74.5 cal Sz10 16Com"
Composite Insulating gloves with ARC Flash protection. Standards IEC 60903, 61482-1-2, ASTM F2675
The Regeltex Class 2 composite glove is for electrical work with maximum voltage of 17,000 volts. It is an essential piGlove Ins Cl3, 26.5kV 73.2cal Sz10 16 C"
Composite Insulating Gloves with ARC Flash protection. Standards IEC 60903, 61482-1-2, ASTM F2675
The Class 3 composite glove is for electrical work with maximum voltage of 26,600 volts. It is an essential piece of PPE designed to protect
Glove Ins Cl4, 36kV 87.7cal Sz10 16 Com"
Composite Insulating gloves with ARC Flash protection The Regeltex Class 4 composite glove is for electrical work with maximum voltage of 36,000 volts. It is an essential piece of PPE designed to protect workers interacting with exposed High VoltaStanco HRC2 Arc Flash 12.4 cal Kit 2
Stanco HRC2 Arc Flash 12.4 cal Kit 2. Contents: Knee Length 50" Coat, GCA Class 0 Electrical Mechanical Arc Flash Gloves, Standard Hood, Australian Designed Standard helmet (for under hood use) , 15" Leggings, GB50 Deluxe
12.4 cal Suit Kit c/w Gear Bag XL
A/F 12.4 cal Suit Kit c/w Std Hood XL
- Stanco Arc Flash ( PPE ) Protective Switching Suit - Clothing Kit. Conforming to Standard: NFPA 70E HRC/CAT 4 ASTM D6413. Available Standard Cal ratings: 8, 12, 21, 25, 40, 44, 57 & 74cal.
40cal ArcFlash Kit CoatTrouserGlove HRC4
Stanco TTK 40 cal Arc Flash kit complete with FR quick adjust helmet to keep the hood from moving on the head. Waist length coat & sleeveless Bib / Trousers made from Westex material, providing excellent protection. Kit comes with US214 Arc FlasPhase Displacement
Real three phase automatic ratio tester for power transformer The ART-3Dâ„¢ series of ratio meters are high precision instruments, designed to measure turn ratios, phase displacements, excitation currents of single phase and three phase power, diPortable Discharge Detector
Partial Discharge Detection and Localization System for Power Transformers The AE-150™ is designed to detect and localize Partial Discharge activity by correlating acoustic and electric sensors’ data. The AE-150™ has many acquisition modesArrester Default Detector
Online partial discharge detector for overhead accessories The ADD™ allows online partial discharge detection on medium voltage accessories such as: Arresters, dry type transformers, bushings, insulators, etc… The partial discharge level is dSCH Insulation Chamfering Stylus Green
The green SCH stylus can make a chamfer on the extremity of the primary insulation.
Diameter: ø16 - 60 mm.
Must be used with the following tools: MF1+/25, MF1+/60, MF3/40, MF3/60, MF3/40-SR, MF3/60-SR, MF3/40-C, MF3/60-CXLPE Insulation Cable Stripper 80-110mm
Alroc LH4 cable tools used by MV-HV jointers to remove the insulation.
Prepare the cable ready for the installation of joints, terminations or connectors.
Maximum cutting depth: 29mm
Cable diameter from 80 to 110mm.
Length 640mSRC-D Adjustable Scoring Stylus Silver
The silver SRC-D stylus can remove the peelable semi-conductor without touching the primary insulation located underneath.
4 scoring depths: 0.4mm / 0.7mm / 0.9mm / 1.1mm.
Diameter: ø16 - 58 mm.
Must be used with the followinXLPE Insulation Cable Stripper 60-80mm
Alroc LH3 cable tools used by MV-HV jointers to remove the insulation.
Prepare the cable ready for the installation of joints, terminations or connectors.
Maximum cutting depth: 24mm.
Cable diameter from 60 to 80mm.
Length 460mSRC Adjustable Scoring Stylus Gold
The gold SRC stylus can remove the peelable semi-conductor without touching the primary insulation located underneath.
4 scoring depths: 0.4mm / 0.7mm / 0.9mm / 1.1mm.
Diameter: ø14 - 58 mm.
Must be used with the following toCable Cutter w/end plastic
INSULATED RATCHET CABLE CUTTER Ø 25 MM WITH INSULATING HEAD COVER 290MM L ALUM 300MMSQ & COPPER 240MMSQ - EN 60900 / IEC 60900. this tool can be used with a wedge with groove 5544E.
LH2 Insulation Cable Stripper 38-60mm
Alroc LH2 cable tools used by MV-HV jointers to remove the insulation to prepare the cable ready for the installation of joints, terminations or connectors.
Maximum cutting depth: 17mm.
Length 425mm, Width 105mm, Height 85mm.<Insulated cutting pliers 190mm
Insulating composite cable cutting pliers.
Standards: EN 60900 / IEC 60900.
Guaranteed up to 1000V.
Length 190mm, Weight 165g
Apllication range: Opening 22mm, Aluminium 35mm2 Copper 16mm2XLPE Insulation Cable Stripper 38-60mm
Alroc XLPE enable a chamfer of 30 mm at the extremity of the insulation of MV cables. For 38 - 60mm cable diameter.XLPE Insulation Chamfer tool 14-40mm
Alroc XLPE enables a chamfer of 30 mm at the extremity of the insulation of MV cables. For 14-40mm cable diameter.
Switch Disc SLTL4A-3AS/3X/4 1ph
NH strip-type fuse-switch-disconnector SLTL4A-3AS/3X/4 690V Rated operating current: 1250A Size: NH4a Busbar distance: 185mm poles: 312 cal Premium Balaclava
ARCCAG10 FLAME RESISTANT AND ARC FLASH RESISTANT BALACLAVA, ATPV 12,1 CAL/CM²EN ISO 11612 (A1 AND A2 B1 C1 F1) / IEC 61482- 2 / EN 61482-1-2 (CLASS 1 ACCORDING TO BOX TEST), ASTM F1959-05 (12,1 CAL/CM², HAF 81,6% ACCORDING TO OPEN ARC ME
24 cal Premium Balaclava
ARCCAG24ARC FLASH BALACLAVA - ATPV 24,7 CAL/CM²EN ISO 11612 / EN 61482-1-2 / ASTM F1506 / NFPA70EUse:Provides protection of the face and the neck against thermal hazards, especially against burn hazards from an arc flash. It does not spread t
Glove Ins Cl1, 7.5kV 42.2 cal Sz10 16 C"
Composite Insulating gloves with ARC Flash protection. Standards IEC 60903, 61482-1-2, ASTM F2675
The Class 1 composite glove is for electrical work with maximum voltage of 7,500 volts. It is an essential piece of PPE designed to protect w
Glove Ins Cl00, 500V 26.3cal Sz10 14Com"
Composite Insulating gloves with ARC Flash protection The Class 00 composite glove is for electrical work with maximum voltage of 500 volts. It is an essential piece of PPE designed to protect workers interacting with exposed High Voltage electricMV Bonded semicon scraper 15-240mm
The MV Bonded semicon is a very reliable product, well designed using high quality steel and aluminium. This tool is targeted to get a very long-life duration.
DSP Peelable Semiconductor Lifter
The DSP tool remove and catch the peelable semiconductor at the end of cable.
Diameter: ø10 - 80 mm.
Can be used with the following tools: MF1+/25, SR, SRC, MF1+/60, SRC-D, MF3/40, MF3/60.LV Cable Stripper 6 Sections 16-150mm
ALROC stripping Tool. 6 sections from 16 to 150mm².
Low voltage cable stripper 6 sections. For overhead cable. Enables the user to remove the insulation.
Sections : 16 - 25 - 35 - 54,6 - 70 - 150m²
Length 130mm, Width 130mGripall Stick 1.22m/4ft OAL Orange
Gripall Stick 1.22m/4ft OAL Orange. To suit shotgun ring / gripper spindles. This gripall / shotgun hot stick is an essential piece of Insulating equipment to protect technicians when working with high voltage machines and conductors, where a
Lead Sheath Spreader LV & MV Cables
The Alroc EVP enables the user to flare and spread the lead sheath or the tabs made from the lead sheath. Spread without damaging underlying layers.
Road Shell Cable Cover 2x90-4x40mm
Road Shell Cable Cover - suits Warm Climate Low Profile 120mm. Two channels 92mm & four channels 40mm
Rubber Goods Cleaner 200ml Spray Bottle
Regeltex RGX-1704 is a quick drying professional rubber cleaner in a ready to use 200ml spray bottle.RGX is specifically developed to properly clean rubber insulating materials such as gloves and mats. For best results we recommend to us
Plastic UV Glove Box Suit Classes 0-4
The BGT Sibille Safe Glove box has been designed for the safe storage and protection of electrical gloves. This unit is portable with folding handle, it can also be wall mounted for use in electrical substations, technical rooms etc.
Pneumatic Glove Tester
TESTER FOR INSULATING GLOVES
Use: The purpose of the tester is to ensure that the glove is absolutely air-tight.
PFlex 9.4 Cal HRC2 FR Glove size 10 (XL)
9.4 cal HRC2 Kevlar Glove - Cut and Fire Resistant (FR) Size 10
See below for product detail >>
Aladin Electric Field Detector 10-400kV
Individual electric field detection with headlamp.
For MV Overhead lines 10 000 to 69 000V, work from elevated platforms only.
Provide extra safety level for workers operating near energized equipment.
Dimensions: 87x60x34mm.
WLector Wireless Volt Reader MV handheld Meter wireless signals Lector Detector
Handheld Wireless Volt Reader (c/w VECTOR)Glove Bag Vinyl 17inch(425mm) w/clip EOL
Hylec glove bag is made from PVC material. This will suit to store all classes of insulating glove and leather over glove with 36cm (14 inch) length from Class 00 to 4.
Ex GST $39.00Voltage detector DC 400-3600V 157621
FAMECA Bipolar voltage detector. Composed with a probe and a pole that allows the detection of DC voltages as well as AC.
Rated voltage: 400V to 3600V.
Meta case size: 450x345x127mm
Weight: 1.75kg.HV voltage detector 250 to 440kV
FAMECA high voltage DC detector. Compact optical and acoustic detector with LEDs.
Rated voltage: 250 000 to 440 000 V DC
Length: 350mm, Diameter: 80mm
Weight: 0.550kg.HV voltage detector 450 to 800kV
FAMECA high voltage DC detector. Compact optical and acoustic detector with LEDs.
Rated voltage: 450 000 to 800 000 V DC
Length: 350mm, Diameter: 80mm
Weight: 0.550kg.HV voltage detector 50 to 100kV
FAMECA high voltage DC detector. Compact optical and acoustic detector with LEDs.
Rated voltage: 50 000 to 100 000 V DC
Length: 350mm, Diameter: 80mm
Weight: 0.550kg.Indoor Kit with TAG5010 4-230kV QLD
Fameca's Wireless Contact Phase Detector supplied by Hylec is a contact phase detector for three phase network with nominal voltages from 4kV up to 230kV. It uses 2 wireless instruments a Transmitter and a Receiver that is pared together and has a
Phasor5K Series 4-230kV+case50Hz TV1.8kV
TAG5010 4-230 AU 50HZ Also available in 4-132kV and 11-33kV. Fameca HV Wireless Phasor Wide Range contact, Outdoor, On Board test, sunrise head, audio visual. 50Hz proven in Australian conditions for over 20 years
&n